Use este identificador para citar ou linkar para este item: https://repositorio.inpa.gov.br/handle/1/37800
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSilva, Raiza F. da-
dc.contributor.authorRocha, Siomara D. da-
dc.contributor.authorMenegário, Amauri Antônio-
dc.contributor.authorPedrobom, Jorge Henrique-
dc.contributor.authorSulato, Everton Tiago-
dc.contributor.authorLuko, Karen Silva-
dc.contributor.authorElias, Lucas Pellegrini-
dc.contributor.authorOliveira, Lucia M. de Souza-
dc.contributor.authorJunior, Ézio Sargentini-
dc.date.accessioned2021-07-06T19:24:17Z-
dc.date.available2021-07-06T19:24:17Z-
dc.date.issued2021-
dc.identifier.urihttps://repositorio.inpa.gov.br/handle/1/37800-
dc.description.abstractThis study compares the techniques cold vapour atomic fluorescence spectrometry (CV-AFS) and inductively coupled plasma mass spectrometry (ICP-MS) for the determination of Hg in biological samples (hepatic tissue from marine tetrapods). Acid digestions were performed for the samples and aliquots of them were analysed by ICP-MS and CV-AFS. To minimize the Hg memory effect in its determination by ICP-MS, gold (200 μg L-1 in 5% v v-1 HCl) was added to the sample digests. The detection limits were 0.02 mg kg-1 for ICP-MS and 0.01 mg kg-1 for CV-AFS. Accuracy was assessed by the calculation of the recovery obtained from TORT-3 (lobster hepatopancreas) certified reference material analysis. Accurate results were obtained for both CV-AFS and ICP-MS. The comparison of the results obtained for hepatic tissue with and without lyophilization showed a significant difference among them (at 95% of confidence level), evidencing losses of Hg in the lyophilization process. © 2021 Sociedade Brasileira de Quimica. All rights reserved.pt_BR
dc.language.isoenpt_BR
dc.relation.ispartofVolume 44 Págs.: 64 - 69pt_BR
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/br/*
dc.subjectCV-AFSpt_BR
dc.subjectMercúriopt_BR
dc.titleDetermination of mercury in liver of marine tetrapods by cold vapor atomic fluorescence spectrometry and inductively coupled plasma mass spectrometry in biological samples: A systematic comparison between the two techniquespt_BR
dc.title.alternativeDeterminação de mercúrio em fígado de tetrápodes marinhos por espectrometria de fluorescência atômica acoplada a geração de vapor frio (CV-AFS) e espectrometria de massa com fonte de plasma indutivamente acoplado (ICP-MS): uma comparação sistemática entre as duas técnicaspt_BR
dc.typeArtigopt_BR
dc.identifier.doi10.21577/0100-4042.20170675-
dc.publisher.journalQuimica Novapt_BR
Aparece nas coleções:Artigos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Determination.pdf64,06 kBAdobe PDFVisualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons