Use este identificador para citar ou linkar para este item: https://repositorio.inpa.gov.br/handle/1/38373
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSousa, Edinaira Sulany Oliveirade-
dc.contributor.authorPinheiro, Silviane Bezerra-
dc.contributor.authorAlves Cortez, Ana Cláudia-
dc.contributor.authorCruz, Kátia Santana-
dc.contributor.authorSouza, Érica Simplíciode-
dc.contributor.authorMelhem, Marcia de Souza Carvalho-
dc.contributor.authorFrickmann, Hagen-
dc.contributor.authorSouza, João Vicente Bragade-
dc.date.accessioned2022-02-11T20:12:20Z-
dc.date.available2022-02-11T20:12:20Z-
dc.date.issued2021-
dc.identifier.urihttps://repositorio.inpa.gov.br/handle/1/38373-
dc.description.abstractA common strategy in antifungal susceptibility testing is the utilization of the standardized protocol based on the microbroth dilution assay approach as described by the Clinical Laboratory Standards Institute (CLSI) (M27-A4). One major problem for laboratories in resource-limited countries with this protocol arises from the use of expensive culture media like RPMI-1640 and 3-N-morpholinopropanesulfonic acid (MOPS) buffer. One approach of circumventing this problem in cases of economic need is the evaluation of alternative culture media and buffers. The overall goal of this work was to investigate the influence of modifications in the protocol M27-A4 on diagnostic reliability. We performed univariate analyses evaluating (1) 2 different culture media (YNB and modified SAB); (2) three different buffers (sodium bicarbonate, Tris-HCL, and phosphate), as well as the influence of inoculum concentration (102, 103, 104, 105 cells/mL), the influence of incubation time, and the influence of the assessment mode (visual, biological dye, and spectrophotometer). Our results suggested that (1) RPMI-1640 may be substituted by modified SAB and (2) MOPS buffer may be substituted by Tris-HCl buffer for defined analyses. By comparing the CLSI protocol and the alternative protocol proposed in the present study (modified SAB and Tris-HCl buffer) for the assessment of fluconazole susceptibility of eighteen yeasts (clinical isolates), similar results with both methodologies were recorded. We feel that this study should stimulate a discussion on the feasibility and evolution of the M27-A4 protocol in order to include pragmatic alternatives for resource-limited settings.pt_BR
dc.language.isoenpt_BR
dc.relation.ispartofVolume 101, Edição 3pt_BR
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/br/*
dc.subjectYeastpt_BR
dc.subjectMicrobroth dilutionpt_BR
dc.titleModifications of antifungal sensibility testing as suggested by CLSI document M27-A4: proposal for using different culture medium and bufferpt_BR
dc.typeArtigopt_BR
dc.identifier.doihttps://doi.org/10.1016/j.diagmicrobio.2021.115488-
Aparece nas coleções:Artigos
IPUB

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Repositório do INPA.docx11,04 kBMicrosoft Word XMLVisualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons