dc.description.abstract | The Fluorescence Image Analyzer (FLIMA) software was developed for the quantitative analysis of images generated by fluorescence in situ hybridization (FISH). Currently, the images of FISH are examined without a coefficient that enables a comparison between them. Through GD Graphics Library, the FLIMA software calculates the amount of pixels on image and recognizes each present color. The coefficient generated by the algorithm shows the percentage of marks (probes) hybridized on the chromosomes. This software can be used for any type of image generated by a fluorescence microscope and is able to quantify digoxigenin probes exhibiting a red color, biotin probes exhibiting a green color, and double-FISH probes (digoxigenin and biotin used together), where the white color is displayed. © 2017 The Authors. | en |
dc.language.iso | en | pt_BR |
dc.relation.ispartof | Volume 16, Número 1 | pt_BR |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Brazil | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | * |
dc.subject | Biotin | en |
dc.subject | Digoxigenin | en |
dc.subject | Algorithm | en |
dc.subject | Chromosome | en |
dc.subject | Color | en |
dc.subject | Controlled Study | en |
dc.subject | In Situ Hybridization, Fluorescence | en |
dc.subject | Image Analysis | en |
dc.subject | Quantitative Analysis | en |
dc.subject | Evaluation Study | en |
dc.subject | In Situ Hybridization, Fluorescence | en |
dc.subject | Microscopy, Fluorescence | en |
dc.subject | Image Processing | en |
dc.subject | Nucleic Acid Hybridization | en |
dc.subject | Procedures | en |
dc.subject | Software | en |
dc.subject | Chromosomes | en |
dc.subject | Evaluation Studies As Topic | en |
dc.subject | Image Processing, Computer-assisted | en |
dc.subject | In Situ Hybridization, Fluorescence | en |
dc.subject | Microscopy, Fluorescence | en |
dc.subject | Nucleic Acid Hybridization | en |
dc.subject | Software | en |
dc.title | Fluorescence image analyzer - FLIMA: Software for quantitative analysis of fluorescence in situ hybridization | en |
dc.type | Artigo | pt_BR |
dc.identifier.doi | 10.4238/gmr16019658 | - |
dc.publisher.journal | Genetics and Molecular Research | pt_BR |
Aparece nas coleções: | Artigos |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
artigo-inpa.pdf | 295 kB | Adobe PDF | Visualizar/Abrir |
Este item está licenciada sob uma Licença Creative Commons